
DN100–DN1000 · Air · HVAC · Fume Extraction · Cleanroom
Reguvale’s ventilation butterfly valves are designed for low-pressure, high-volume air flow control in HVAC systems, industrial ventilation, fume extraction and cleanroom applications. Available in large sizes from DN100 to DN1000 — among the largest in the industry.
Lightweight construction with excellent flow characteristics makes them ideal for air handling units, duct isolation, fume hoods and ventilation mains where pressure drop must be minimized.
Body materials: ductile iron GGG50 (epoxy coated) or carbon steel. Available with manual lever, worm gear, electric actuator or pneumatic actuator for automated air flow control and remote damper operation.
DN100 to DN1000 covers virtually all air handling and ventilation applications.
Streamlined disc gives excellent flow with minimal pressure loss in air ducts.
Much lighter than gate or globe valves of the same size, easy to install in ducts.
Fast 90° open-close with lever, gear, electric or pneumatic actuator.
Electric and pneumatic actuated options for remote damper control in building automation.
Epoxy-coated ductile iron body for long life in air handling and fume service.
| Parameter | Specification |
|---|---|
| Design | Concentric, Ventilation / Air Service |
| Body Material | Ductile Iron GGG50 (Epoxy Coated) / Carbon Steel WCB |
| Disc Material | Ductile Iron / SS304 / SS316 |
| Size Range | DN100 – DN1000 |
| Pressure Rating | PN6 / PN10 (low pressure) |
| Medium | Air, gas, fume |
| Temperature | -20°C to +120°C (EPDM seat) |
| End Connection | Wafer / Flanged / Lug |
| Operation | Manual Lever / Gear / Electric / Pneumatic |
| Certification | ISO 9001:2015, SGS-CSTC factory audit report (on request) · MTC per batch |
Air handling units, duct isolation and volume control in commercial buildings.
Exhaust and supply air control in factories, warehouses and process plants.
Laboratory and industrial fume hood exhaust isolation.
Air flow control in pharmaceutical, electronics and food cleanroom environments.
Ventilation valves are chosen for low pressure drop and low weight, not for tight shut-off. Specifying one for the wrong duty is the usual error.
These valves are rated PN6 / PN10 and designed for air, gas and fume at −20 to +120°C. They are not a substitute for a pressure-rated liquid isolation valve.
A ventilation valve is often one size smaller than the duct and still passes the required volume. Give us the airflow (m³/h) and the permitted pressure drop, and we will confirm the size.
DN100 to DN1000 covers most HVAC and industrial ventilation work, but duct flanges vary. State the flange drilling you have.
Building automation needs the electric actuated version with 0–10 V, 4–20 mA or floating control. Retro-fitting an actuator to a manual valve later costs more than specifying it up front.
Torque rises roughly with the cube of the diameter on a damper. On DN600 and above, confirm the actuator selection with us rather than assuming the next size up will do.
From roughly DN400 upward the valve should not hang from the ductwork. Provide a support or a flanged spool so the duct carries no valve weight.
The disc should open against the flow so that airflow assists closure rather than forcing the disc open.
Turbulence from an elbow immediately upstream distorts the flow and makes volume control unpredictable. Two to three diameters of straight duct is a reasonable minimum.
EPDM is fine for ordinary air. Chemical fume or kitchen exhaust needs a seat checked against the actual contaminants.
The pressure rating is PN6 / PN10 air duty, not a liquid isolation rating.
A DN800 valve is heavy enough to distort light-gauge ductwork.
Ventilation valves control flow; they are not intended as bubble-tight isolation.
A ventilation butterfly valve is a large-diameter, low-pressure butterfly valve used to control air flow in HVAC systems, industrial ventilation, fume extraction and cleanroom applications.
Ventilation butterfly valves are available from DN100 up to DN1000, covering most air handling and industrial ventilation applications.
Yes. Ventilation butterfly valves can be fitted with manual lever, gear operator, electric actuator or pneumatic actuator for automated air flow control.
Send us your duct size and application — we reply within 24 hours with a tailored quotation.
Request Quote →